Mitsubishi Electric VRF System

Mitsubishi Electric VRF
Mitsubishi Electric VRF Systems | 0Degrees Airconditions Madhapur Hyderabad

Mitsubishi Electric CITY MULTI VRF Systems

Hyderabad's Most Advanced HVAC Solution

Revolutionary Compressor Technology | Mitsubishi Electric VRF HVAC System

In-House Inverter Compressor

Mitsubishi Electric's proprietary compressor delivers unmatched efficiency and reliability through complete vertical integration:

  • Industry-leading COP of 5.55 - Highest energy efficiency in class
  • Low-pressure shell design - Prevents overheating with top-discharge gas flow
  • 10%-100% variable capacity - Precise temperature matching to demand
  • Optimized motor cooling - Extends component lifespan by 30%
Technical Advantage | Mitsubishi Electric VRF : Complete in-house development ensures perfect compatibility between compressor, refrigerant circuits, and control systems.

Extended Temperature Range Technology | Mitsubishi Electric VRF System

Precision Cooling Down to 14°C

For specialized applications requiring temperatures below standard comfort levels (19°C):

  • Compatible Units: Floor-standing, Built-in floor units, X-ray cassette, Ducted models
  • Enhanced Operation: Higher fan speed (standard on all except SMALL Y PUMY series)
  • Professional Applications: Sports centers, laboratories, medical facilities

Emergency Backup Functionality

Uninterrupted Climate Control

Available on Y Series and R2 Series models:

  • 4 hours continuous operation during malfunctions
  • Activation: Via any connected remote control
  • Smart Redundancy: Automatic load redistribution

Connected Indoor Unit Variations

64+ Configurations for Any Space

Mix and match these indoor unit types on the same VRF system:

Design Flexibility: Up to 64 indoor units can connect to a single outdoor unit with:
  • Maximum piping length: 120m
  • Elevation difference: 50m
  • 3-pipe heat recovery options

Specialty Indoor Units

Unit Type Special Features Applications
Fresh Air Ventilation Heat recovery ventilators Hospitals, Labs
High Static Ducted Up to 150Pa pressure Large auditoriums
Corridor Units Narrow 200mm depth Hotels, Apartments
Underfloor Units Low-profile 150mm height Luxury residences

Advanced System Technologies

Intelligent Rotation Function

Automatic component management for extended system life:

  • Balances runtime across all connected units
  • Prevents uneven compressor wear
  • Optimizes maintenance schedules

Evaporating Temperature Control (ETC)

Dynamic cooling optimization:

  • Real-time refrigerant temperature adjustment
  • Smart Mode reduces energy waste at partial loads
  • Maintains ideal system pressures

System Specifications

Technology Performance Available Models
Inverter Compressor COP 5.55, 10-100% capacity All current models
Extended Cooling Down to 14°C Floor-standing, Ducted models
Emergency Backup 4 hours operation Y Series, R2 Series
Rotation Function Automatic load balancing Y Series, R2 Series
Indoor Unit Capacity 64 units per system All configurations

Frequently Asked Questions

Q: How does Mitsubishi's compressor achieve higher efficiency than competitors?

A: Mitsubishi Electric VRF proprietary design combines low-pressure shell architecture with precision inverter control and optimized refrigerant flow paths, reducing energy losses by up to 40% compared to conventional compressors.

Q: How energy efficient are Mitsubishi Electric VRF systems compared to conventional AC?

A: Mitsubishi VRF systems are 30-40% more energy efficient than traditional systems, with COP ratings up to 5.55 and inverter technology that eliminates energy waste.

Q: What maintenance is required for systems operating in extended cooling mode?

A: We recommend quarterly inspections for systems regularly operating below 16°C, including refrigerant level checks and compressor diagnostics. Our service plans include specialized maintenance for these applications.

Q: Can the emergency backup function be extended beyond 4 hours?

A: The 4-hour limit is designed for system protection. For mission-critical applications, we recommend installing redundant systems or backup power solutions.

Q: How does the Rotation Function impact energy efficiency?

A: By evenly distributing workload, the Rotation Function actually improves long-term efficiency by preventing individual components from operating outside their optimal performance range.

Q: Can I mix different indoor unit types on one system?

A: Absolutely! Our VRF systems support any combination of wall-mounted, ceiling, ducted, and floor units, allowing complete customization for each zone.

Q: What's the lifespan of these VRF systems?

A: With proper maintenance, our systems typically operate 15-20 years. The Rotation Function extends this by preventing uneven component wear.

Ready for Next-Generation Climate Control?
Top VRF AC Brands in India
Mitsubishi Electric VRF Dealer
Best VRF system for commercial buildings

Commercial VRF installation contractors in Hyderabad

Our Mitsubishi-certified engineers will design the perfect solution for your space

Contact our VRF specialists today for a free consultation

9052216818

24/7 support | Free commercial consultation | Extended warranties available

Previous Post